304lv wire. The material is vacuum re-melted, giving it a more uniform chemistry. 304lv wire

 
 The material is vacuum re-melted, giving it a more uniform chemistry304lv wire  Arc+VAR or ARC+ESR is better

This process yields a more uniform chemistry with minimal voids and contaminants. 2023 ULBRICH SHAPED WIRE, INC. 433 4. Our main materials are stainless steel and alloy steel, and the raw materials we use are from the biggest and most well-known steel mills in China, we can supply wire in sizes ranging from 0. Material: Stainless Steel Medical Wire: Grade: 302, 304V, 304LV, 316LVM, Custom 455, Biodur108: Standard: ASTM A313, A313M, A276, F899, A564/A564M, F2229, F138ISO 5832-1DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). It is a very strong, safe, and non-toxic material with corrosion-resistant properties, being mechanically strong and highly flexible so that it can endure deformation and remain intact. It is a very strong, safe, and non-toxic material with corrosion-resistant properties, being mechanically strong and highly flexible. The chemistry of 304LV makes it less susceptible to sensitization. 83 (120) 0. Then as a refinement to the purity and homogeneity of the metal, 304LV is Vacuum Arc Remelted (VAR). Mechanical Properties %CW Y. Oct. Leading Supplier for Spring Wire, Nickel Alloy Wire, Welding Wire, Shaped Wire. ASTM F138 Stainless Steel 316LVM Medical Wire Flexible Wire. 304V will fully anneal at 1010-1121°C in just a few minutes. The "L" means low carbon as compared to 304V. 3 CP Ti Gr. 824 2. 275. 822 0. 722 products. Fatigue Failure Analysis of Enhanced 35N LT®. Composite wire with enhanced radiopacity, elasticity, and electrochemical behavior. some nuclear and medical applications specify it must be VIM/VAR. Flatwire, often referred to as ribbon wire, is commonly used in devices designed to reduce catheter profiles or increase available lumen size. It is a very strong, safe, and non-toxic material with corrosion-resistant properties, being mechanically strong and highly flexible so that it can endure deformation and remain intact. DFT® wire. June May April Mar. Flatwire, often referred to as ribbon wire, is commonly used in devices designed to reduce catheter profiles or increase available lumen size. Unalloyed Commercially Pure (CP) Titanium is represented by four distinct grades, specifically 1, 2, 3 and 4. 455™ Alloy 31. Ulbrich Specialty Wire Products 692 Plant Road P. 675 16. Stainless Steel - Fort Wayne Metals. End uses include: catheters, guide wires, small parts made from straightened and cut wire and orthodontic uses. Heat-Shrink Tubing. 768 NIS80 5. 262 316LV 1. In wire form, cold worked 302 will gain tensile strength when stress relieved at 350-427°C for 4-6 hours. Applications Flatwire Shaped wire Strands and cables HHS® tubes SLT® wire Composites Stainless grade 304V wire is a commonly used alloy for non-implantable medical devices. End uses include If you need stainless steel wire that performs beyond what is expected of typical alloys, explore our NDR® wire. The melt practice is an enhancement of the standard melt practice for ASTM F-562 material yielding much lower inclusion counts. 302 will fully anneal at 1010-1121°C in just a few minutes. Chemistry 302/304, 304LV, 304V Stainless Steel Cobalt is a naturally occurring trace element within stainless steels. NiTi #1-ELI-DFT®-20%Pt. 83 (120) 0. The wire gauge indicates the electrical wire sizing, as defined by the American Wire (AWG) system. 680 1. 304LV stainless steel 316LVM stainless steel Custom 455® alloy High-performance alloys 35N LT™ alloy MP35N® alloy L-605 alloy FWM™ 1058 alloy FWM™ 1537 alloy Titanium35N LT Melt Practice. 3 CP Ti Gr. This material is received on spools or coils from our parent company, FWMRPC, at intermediate sizes (~ 1. This austenitic stainless steel is initially electric-arc melted. 563 5. In wire form, 304V will gain tensile strength when stress relieved at 350-427°C . It is. Characterizing Fatigue Response of Nickel-titanium. 916 6. 732 8020P 3040P 1. The n gauge wire's cross sercional area A n in square inches (in 2 ) is equal to pi divided by 4 times the square wire diameter d in inches (in):No category World-class solutions in medical-grade materials. A276 304V/304LV Stainless Steel Wire for Medical Fine Wire Medical wire is used in the medical industry as surgical instruments, implants, and devices. 304L is an ultra-low carbon stainless steel with a carbon content reduced to less than 0. Feb. 4301, X5CrNi18-10; 304H, S30415, 1. 175Suture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. It maintains excellent corrosion resistance in most situations outside of marine environments and maintains its properties in high temperature situations. 040” (1. 717 8020P 4. Product Capability Wire. Flatwire, often referred to as ribbon wire, is commonly used in devices designed to reduce catheter profiles or increase available lumen size. Not as corrosion. 304LV stainless steel 316LVM stainless steel Custom 455® alloy High-performance alloys 35N LT™ alloy MP35N® alloy L-605 alloy FWM™ 1058 alloy FWM™ 1537 alloy Titaniumthe manufacturing of medical grade wire. 687. 462 3. 59 (85) 0. 1 CP Ti Gr. The L in 304/L refers to a lower carbon content to allow for greater corrosion protection when welding. Our mission is to continually improve the quality of our products, the speed with which we respond to customers’ requests,. Superalloy Whitepapers. Sept. Then as a refinement to the purity and homogeneity of the metal, 304LV is Vacuum Arc Remelted (VAR). 907 5. 08%, whereas grade 304L stainless steel has a maximum carbon content of 0. Alloy 625. (psi) % Elongation (10" gauge length) 0%. 747 2. 764 5. 48 (70) 0. MP35N is an excellent combination of strength and corrosion resistance. Fort Wayne Metals uses two manufacturing techniques to yield different types of. 2023 ULBRICH SHAPED WIRE, INC. In grade 304 stainless steel, the maximum carbon content is set at 0. Ti 6Al-4V ELI. 304V is the most popular of all our alloys for use in non-implantable medical devices. The most common alloys used for medical device applications are 302, 304V, 304LV and 316LVM. If you are looking for a durable and versatile 16 gauge 304 stainless steel rebar tie wire, check out this product on Amazon. kualitas tinggi Kawat Tajuk Dingin Stainless Steel Magnetik Rendah Untuk Pemrosesan Dalam Konstruksi dari Cina, Kawat Pos Dingin Stainless Steel pasar produk, dengan kontrol kualitas yang ketat Kawat Pos Dingin Stainless Steel pabrik, menghasilkan kualitas tinggi Kawat Tajuk Dingin Stainless Steel Magnetik Rendah Untuk Pemrosesan Dalam. Fort Wayne Metals utilizes state-of-the-art equipment and processing techniques to provide precision drawn Ti 6Al-4V ELI. (psi) % Elongation (10" gauge length) 0%. We produce spring wire, electrolytic polished wire, fine wire, wire for netting, hose wire, welding wire, cold heading, locking wire, and other products. 承载板 承重板 拉. MTSCO - Since 2006, ASTM A313 Medical Wire For Slae, China ASTM A313 Medical Wire Manufacturer, Supplier. Typical applications include safety wires in a catheter guidewire, helical coils in a catheter guidewire and braiding wire. Cyclic Potentiodynamic Survey of Medical Materials. Product Capability Wire. controlled by a reduced carbon content in 304LV. Oct. Includes material certificates. Sept. Given the same amount of cold work, 302 is harder than 304. Stainless Steel 304V/304LV Medical Wire Non-toxic Fine Wire Medical wire is used in the medical industry as surgical instruments, implants, and devices. Our main materials are stainless steel and alloy steel, and the raw materials we use are from the biggest and most well-known steel mills in China, we can supply wire in sizes ranging from 0. Ulbrich Precision Flat Wire W304LV-7894-1470, 0. Strip, Coil, Foil & Wire, ASTM A 276, ASTM A 313, ASTM A 666. As a result of extreme compressive forces imparted during the<br />. Fort Wayne Metals uses two manufacturing techniques to yield different types of. 496 CA450 2. Typical uses include medical devices or implants, aerospace applications and pressure vessels. It is the most widely used stainless spring wire because of its. VIM/VAR is superior. A276 304V/304LV Stainless Steel Wire for Medical Fine Wire. 999 316LV 2. 55” (14 mm). 339-8839 Jewelry in 304LV stainless steel. Sept. Characterizing Fatigue Response of Nickel-titanium. 596185: 1 GL: Valorem VPS-250LV Grey Surfacer LV A low VOC 2K polyurethane primer surfacer that provides good adhesion, high build, easy coverage, and optimal topcoat appearance. SURCHARGES Alloy Dec. O. 941 HX000 8. Our engineering team can help you determine which materials and fill ratio are best suited for your application. Jul. the manufacturing of medical grade wire. Fort Wayne Metals uses two manufacturing techniques. Download. 304V will fully anneal at 1010-1121°C in just a few minutes. A286 5. 866 CRMLD. CONICHROME™ CP Ti Gr1. Our engineering staff can assist you in determining which alloy best suits your application. 5V Ti-Beta 3 Ti-Beta C 302 304V 304LV 316LVM DFT® (Composites) 35N LT® MP35N® L-605 (HAYNES® 25) DBS® FWM. S. 200 4. Oct. End uses in the medical field are: pacing leads, stylets, catheters and orthopaedic cables. Feb. SURCHARGES Alloy Dec. 053. Type 304 is the most versatile and widely used stainless steel. Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility. June May April Mar. In wire form, 304V will gain tensile strength when stress relieved at 350-427°C. CP titanium is ordered in relation to the corrosion resistance, formability (ductility) and strength requirements of a specific application. 304LV will fully anneal at 1010-1121°C in just a few minutes. A reducing atmosphere is preferred, but inert gas can be used. In addition, the ASTM standard A313 for 304 stainless steel does controlled by a reduced carbon content in 304LV. June May April Mar. SURCHARGES Alloy Dec. 727 1. 304 Stainless Steel Pipe/Tube, Flanges, Fittings. 모든 철강 제품은 높은 품질과 경쟁력있는 가격으로 제공됩니다. Nov. (MTSCO), MTSCO, Since 2006, China supplier of stainless steel pipe/tube/tubing, seamless steel pipe, welded steel pipe, stainless steel flange, pipe fitting. 462 3. Sept. Mechanical Properties %CW Y. Our single crystal natural diamond dies will take your stainless steel wire from0. 907 5. 581 1. 4 Ti 6Al-4V ELI Ti 6Al-7Nb Ti 3Al-2. In wire form, 304V will gain tensile strength when stress relieved at 350-427°C. Chemistry DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP) Titanium; Flatwire eratures. Jan. NiTi #1-ELI-DFT®-20%Pt. Stainless grade 304LV is the low-carbon variant of 304V, making it less susceptible to sensitization and more corrosion resistant when worked to high temperatures. You can also compare it with other related products on the same site and find the best deal. Due to its unique properties, FWM® 1537 has great potential in any industrial application that requires high strength, wear and corrosion resistance, for instance in aerospace bushings and bearings. Austenitic steels have austenite as their primary phase. An Investigation of Diverse Surface Finishes on Fatigue. Apply heat to seal and insulate electrical wiring and connections. Type 304/304L is a versatile, general purpose stainless steel with good resistance to atmospheric corrosion, and to many chemicals and food and beverages. A reducing atmosphere is preferred, but inert gas can be used. High quality Low Magnetic Stainless Steel Cold Heading Wire For Construction Deep Processing from China, China's leading Stainless Steel Cold Heading Wire product market, With strict quality control Stainless Steel Cold Heading Wire factories, Producing high quality Low Magnetic Stainless Steel Cold Heading Wire For Construction Deep Processing. Aug. A286 5. There is a carbide precipitation phenomenon that occurs between 427 and 899°C that reduces the corrosion resistance of the alloy. It is. Nov. 304L Stainless Steel UNS S30403 – 304L is corrosion-resistant up to a maximum temperature. 808 4. It is a very strong, safe, and non. Optimization of melt chemistry and properties of drawn filled tube. Because of its excellent corrosion resistance, mechanical strength and fatigue resistance combined with high elastic modulus, FWM 1058 Alloy wire and rod is an attractive candidate for surgical implants. 304LV 3. This stainless steel grade shows good ductility in the annealed condition, and can be readily drawn and formed. 304 Stainless Steel UNS S30400 Strip Wire 304L Stainless Steel UNS S30403 Strip WireChemistry Physical Properties Thermal Treatment In wire form, 304V will gain tensile strength when stress relieved at 350-427°C. End uses in the medical field are: pacing leads, stylets, catheters and orthopaedic cables. Jul. Austenitic Grades. In reality, all three are 304 stainless steel based on their chromium-nickel composition, which contains 18% chromium (Cr) and 8% nickel (Ni). NiTi #1-DFT®-20%Pt. June May April Mar. S. It is a very strong, safe, and non-toxic material with corrosion-resistant properties, being mechanically strong and highly flexible so that it can endure deformation and remain intact. Applications. 4948 chemical composition and 1. the manufacturing of medical grade wire. 302 will fully anneal at 1010-1121°C in just a few minutes. Mechanical Properties %CW Y. Oct. 372 316LV 1. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownFlatwire, often referred to as ribbon wire, is commonly used in devices designed to reduce catheter profiles or increase available lumen size. Find many great new & used options and get the best deals for Thermocouple Wire 60% Platinum 40% Rhodium 0. For spring applications, it is usually offered in cold-drawn conditions. 682 12. Metallurgy, Plymouth Tube. Then as a refinement to the purity and homogeneity of the metal, 304LV is Vacuum Arc Remelted (VAR). ) produced mean UTS values that were similar to wire with about 20-30% cold work. 304LV 2. (psi) U. NiTi #1-DFT®-30%Pt. 304LV. A probabilistic approach to modeling microstructural fatigue. As a leading provider of 304 stainless steel welding wire, we offer a diverse selection of products and wire forming services. This is why the “L” in 304L can be interpreted as meaning extra-low carbon. End uses include: catheters, guide wires, small parts made from straightened and cut wire and orthodontic uses. SLT wire can be produced from the following alloys: - 304V - 304LV - 302 - 301 - 35N LT® - 316LVM - FWM 1058® - Titanium Fort Wayne Metals is a leading manufacturer of medical grade precision materials. 304LV will fully anneal at 1010-1121°C in just a few minutes. NiTi #1-DFT®-30%Pt. 845 2. This alloy has been vacuum arc remelted to yield a more uniform chemistry with minimal voids and contaminants. (psi) U. The same publication lists the annealed UTS as 90 ksi and 20% cold worked UTS as 106 ksi. Aug. 03%. This process yields a more uniform chemistry with minimal voids and contaminants. (Sensitization is the reduction in a material’s corrosion resistance due to exposure to elevated temp-eratures. 606 1. This results in improved fatigue life of as-drawn wire by as. the manufacturing of medical grade wire. Finishes for 316LS See moreFort Wayne Metals Resource library 304LV Melt Practice This austenitic stainless steel is initially electric-arc melted. 12/95] Continue to: prev: 11B. Materials worked with include 304V and 304LV stainless steel, 35NLT®, and DFT® composites. In wire form, cold worked 302 will gain tensile strength when stress relieved at 350-427°C for 4-6 hours. S. T. Medical wire is used in the medical industry as surgical instruments, implants, and devices. DFT® wire. Feb. Mechanical Properties. Surface roughness can. Aug. Jul. 304LV is harder and less flexible than 316L. Custom 455. 321. Have Nitinol, 35N LT® or 304V wire shipped to you in three business days. ) Because of this feature, 304LV is recommended when exposure to 427-649°C is likely. Its applications include surgical instruments, medical implants, catheters, guide wires, springs and needles, and orthodontic wire. NiTi #1-DFT®-30%Pt. Diameter RangeSuture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. SURCHARGES Alloy Dec. When the results of the tensile testing on the heat treated tubes are compared to the FWM published data for 304LV it appears that the vacuum and argon heat treatments (at 575 and 655° C. 65. The Influence of Melt Practice On Final Fatigue. Excellent corrosion resistance in broad range of industrial and chemical settings. 811 0. Jul. MTSCO, ASTM/JIS/EN 316LVM Stainless Steel Medical Wire with Corrosion-resistant Property, China Factory Price, Stainless Steel Wire Manufacturer, Supplier304LV 304V 316LVM Custom 455® Nitinol Wire USN®. 692 NIS80 18. Alloy X-750. A286 2. NiTi #1-ELI-DFT®-10%Pt. 636 1. Fatigue Performance of Nitinol Round Wire with varying cold work reductions. Image Credit: Ulbrich Stainless Steels & Special Metals, Inc. This alloy, usually referred to as Ti 6Al-4V, exhibits an excellent combination of corrosion resistance, strength and toughness. ASTM 9260/6150 Spring Wire Oil Quenched-tempered Shaped Wire: ASTM A313 Stainless Steel 304V/304LV Medical Wire For Guide Wires: 304V ASTM A276 Medical Wire Stainless Steel Highly Flexible Wire: ASTM A580/A581 304/304L/304H/304LN Stainless Steel Annealing / Redrawing Weaving Wire For Mesh Wire:In most cases, electrical cords have three wires: the live wire (L), the neutral wire (N), and the ground wire (G). End uses includethe manufacturing of medical grade wire. Alloy 902 Alloy B. Platinum Nitinol DFT® composite wire. the manufacturing of medical grade wire. Our mission is to continually improve the quality of our products, the speed with which we respond to customers’ requests,. ASTM/JIS/EN 316LVM Stainless Steel Medical Wire with Corrosion-resistant Property. 304L Stainless Steel UNS S30403 – 304L is corrosion-resistant up to a maximum temperature. Committed to global industrial innovation with more stable high-quality products and more efficient professional services. Then as a refinement to the purity and homogeneity of the metal, 304LV is Vacuum Arc Remelted (VAR). Aug. Our engineering team can help you determine which materials and fill ratio are best suited for your application. 4948 mechanical properties. It resists cracking when exposed to heating and cooling cycles. 03%. 900 1. Nov. Then as a refinement to the purity and homogeneity of the metal, 304LV is Vacuum Arc Remelted (VAR). Our 304 welding wire and other wire products represent strong and versatile engineering capabilities. 764 5. 015 I-601. Jul. SURCHARGES Alloy Dec. Fatigue Failure Analysis of Enhanced 35N LT®. 801 1. 016 mm) all Fort Wayne Metals routinely works with the followinggrades of surgical steel: 304 (ASTM F899 · ASTM A276 · ASTM A313/A313M);316 (ASTM A276 · ASTM A580 · ASTM 302 · 304LV · 304V · 316LVM · Custom455?UNS S30400 304LV Stainless Steel - This low carbon steel is melted with an electric arc, then remelted with a vacuum arc (VAR). A286 3. DFT® wire enables the unique ability to match dissimilar materials to provide a variety of properties in a single wire system. English;Mar cheann de na déantúsóirí, soláthróirí agus dáileoirí cruach dhosmálta 304lv as cruach dhosmálta sa tSín, cuirimid fáilte mhór romhat an s30400 cruach dhosmálta 304lv mórchóir a cheannach ónár mhonarcha. Stainless steel is the most versatile metal used in medical devices due to its strength and corrosion resistance properties. 226. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). 5 lb coil with 339 feet of wire, suitable for various applications such as construction, fencing, crafts and more. Our main materials are stainless steel and alloy steel, and the raw materials we use are from the biggest and most well-known steel mills in China, we can supply wire in sizes ranging from 0. 304LV Stainless Steel UNS S30400 Strip, Coil, Foil & Wire, ASTM A 276, ASTM A 313, ASTM A 666 DESCRIPTION This austenitic stainless steel is initially electric-arc melted. A286 3. 5V Ti-Beta 3 Ti-Beta C 302 304V 304LV 316LVM DFT® (Composites) 35N LT® MP35N® L-605 (HAYNES® 25) DBS® FWM. Alloy 304 can be easily welded and is the choice. 972 5. ASTM A313 Stainless Steel 304V/304LV Medical Wire For Guide Wires. The melt practice is an enhancement of the standard melt practice for ASTM F-562 material yielding much lower inclusion counts. Yield strength. Jan. Aug. Custom packaging or spools will be considered based on our equipment capabilities. 304V will fully anneal at 1010-1121°C in just a few minutes. S. News. Nov. A286 1. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). E. 304LV, 304V Stainless Steel Cobalt is a naturally occurring trace element within stainless steels. 1% w/w. com ˝ ˝ ˘˛With round wire as thin as 0. It is still sometimes referred to by its old name 18/8 which is derived from the nominal composition of type 304 being 18% chromium and 8%. This austenitic stainless steel is initially electric-arc melted. Stainless Steel. Feb. This alloy, usually referred to as Ti 6Al-4V, exhibits an excellent combination of corrosion resistance, strength and toughness. When medical device customers go to use bulk, Steeger or Wardwell bobbins they do not want any breakages due to tangling wires. An Investigation of Diverse Surface Finishes on Fatigue. Our mission is to continually improve the quality of our products, the speed with which we respond to customers’ requests,. Jan. (Sensitization is the reduction in a material’s corrosion resistance due to exposure to elevated temp-. Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility. 216 316LV 4. 5 lb coil with 339 feet of wire, suitable for various applications such as construction, fencing, crafts and more. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). CP titanium ranges from grade 1, which has the highest corrosion resistance, formability and. Jul. Other alloys available. Aug. There is a carbide precipitation phenomenon that occurs between 427 and 899°C that reduces the corrosion resistance of the alloy. 683 4. The alloy is initially electric-arc melted followed by a Vacuum Arc Re-melt (VAR). Jul. 603 1. Tantalum wire is a popular material used in electronics capacitors and a critical component in the manufacture of state-of-the art semiconductors. 2023 ULBRICH SHAPED WIRE, INC. Custom 455. Applications The chemistry of 304LV makes it less susceptible to sensitization. CP Ti Gr3. CP titanium ranges from grade 1, which has the highest corrosion resistance. 003" Wire, 304LV SS, 10,200' at the best online prices at eBay! Free shipping for many products! This austenitic stainless steel is initially electric-arc melted. 304LV Strip; 304LV Foil; 304LV Ribbon; Wire. Type 304 stainless steel wire is a general purpose stainless alloy typically composed of 18% chromium and 8% nickel. Free shipping. Faster. Cold-drawn ZM21 and WE43 wires exhibit exceptional strength and ductility. With its exceptional resistance to heat and corrosion, austenitic stainless steel is used extensively in many industries including medical, automotive, aerospace, and industrial. 03%,. 395 2. Oct.